首页 / 院系成果 / 成果详情页

Utrecht Interstitial Applicator Shifts and DVH Parameter Changes in 3D CT-based HDR Brachytherapy of Cervical Cancer.  期刊论文  

  • 编号:
    7bcb8fd2-11ba-4b10-83f7-60d577664cea
  • 作者:
  • 地址:

    [1]Department of Radiation Oncology, China-Japan Union Hospital of Jilin University, Changchun, China E-mail : chengguanghuifl@163.com.

  • 语种:
    英文
  • 期刊:
    Asian Pacific journal of cancer prevention : APJCP ISSN:2476-762X 2015 年 16 卷 9 期 (3945 - 3949) ; 2015
  • 收录:
  • 摘要:

    For brachytherapy of cervical cancer, applicator shifts can not be avoided. The present investigation concerned Utrecht interstitial applicator shifts and their effects on organ movement and DVH parameters during 3D CT-based HDR brachytherapy of cervical cancer.;After the applicator being implanted, CT imaging was achieved for oncologist contouring CTVhr, CTVir, and OAR, including bladder, rectum, sigmoid colon and small intestines. After the treatment, CT imaging was repeated to determine applicator shifts and OARs movements. Two CT images were matched by pelvic structures. In both imaging results, we defined the tandem by the tip and the base as the marker point, and evaluated applicator shift, including X, Y and Z. Based on the repeated CT imaging, oncologist contoured the target volume and OARs again. We combined the treatment plan with the repeated CT imaging and evaluated the change range for the doses of CTVhr D90, D2cc of OARs.;The average applicator shift was -0.16 mm to 0.10 mm for X, 1.49 mm to 2.14 mm for Y, and 1.9 mm to 2.3 mm for Z. The change of average physical doses and EQD2 values in Gyα/β range for CTVhr D90 decreased by 2.55 % and 3.5 %, bladder D2cc decreased by 5.94 % and 8.77 %, rectum D2cc decreased by 2.94 % and 4 %, sigmoid colon D2cc decreased by 3.38 % and 3.72 %, and small intestines D2cc increased by 3.72 % and 10.94 %.;Applicator shifts and DVH parameter changes induced the total dose inaccurately and could not be ignored. The doses of target volume and OARs varied inevitably.;

  • 推荐引用方式
    GB/T 7714:
    Shi Dan,He Ming-Yuan,Zhao Zhi-Peng, et al. Utrecht Interstitial Applicator Shifts and DVH Parameter Changes in 3D CT-based HDR Brachytherapy of Cervical Cancer. [J].Asian Pacific journal of cancer prevention : APJCP,2015,16(9):3945-3949.
  • APA:
    Shi Dan,He Ming-Yuan,Zhao Zhi-Peng,Wu Ning,&Cheng Guang-Hui.(2015).Utrecht Interstitial Applicator Shifts and DVH Parameter Changes in 3D CT-based HDR Brachytherapy of Cervical Cancer. .Asian Pacific journal of cancer prevention : APJCP,16(9):3945-3949.
  • MLA:
    Shi Dan, et al. "Utrecht Interstitial Applicator Shifts and DVH Parameter Changes in 3D CT-based HDR Brachytherapy of Cervical Cancer." .Asian Pacific journal of cancer prevention : APJCP 16,9(2015):3945-3949.
  • 条目包含文件:
    文件类型:PDF,文件大小:
    正在加载全文
浏览次数:11 下载次数:0
浏览次数:11
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部