    Energy based devices (EBD) have been developed, implemented and increasingly applied in thyroid surgery because they can provide a combined dissection and haemostatic effect. In particular, advantages of EBD have been described in terms of efficacious haemostasis, reduction of procedure-associated time, reduced incision length, less operative blood loss and transfusion need, decreased postoperative drain, pain and hospital stay. In addition, EBD are essential for endoscopic procedures. On the contrary, a potential drawback is the increased health care costs. This paper reviews relevant medical literature published on the safety of new devices for achieving hemostasis and dissection around the recurrent laryngeal nerve (RLN).

  • 推荐引用方式
    GB/T 7714:
    Dionigi Gianlorenzo,Wu Che-Wei,Kim Hoon-Yub, et al. Safety of energy based devices for hemostasis in thyroid surgery [J].GLAND SURGERY,2016,5(5):490-494.
  • APA:
    Dionigi Gianlorenzo,Wu Che-Wei,Kim Hoon-Yub,Liu Xiaoli,&Anuwong Angkoon.(2016).Safety of energy based devices for hemostasis in thyroid surgery .GLAND SURGERY,5(5):490-494.
  • MLA:
    Dionigi Gianlorenzo, et al. "Safety of energy based devices for hemostasis in thyroid surgery" .GLAND SURGERY 5,5(2016):490-494.
  • 条目包含文件:
    文件类型:PDF,文件大小:
    正在加载全文
浏览次数:60 下载次数:0
浏览次数:60
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部