首页 / 院系成果 / 成果详情页

A Study to Assess the Accuracy of Adductor Tubercle as a Reliable Landmark Used to Determine the Joint Line of the Knee in a Chinese Population  期刊论文  

  • 编号:
    cfcf243f-bfba-4112-b14d-94474b55f001
  • 作者:
  • 语种:
    英文
  • 期刊:
    JOURNAL OF ARTHROPLASTY ISSN:0883-5403 2017 年 32 卷 4 期 (1351 - 1355) ; APR
  • 收录:
  • 关键词:
  • 摘要:

    Background: Restoring the joint line (JL) is a key element of performing joint arthroplasty, which is a challenging proposition during revision surgeries. We investigated the accuracy of 2 different methods of identifying the JL using the adductor tubercle (AT) as the reference landmark.
    Methods: Standardized protocols for measurements from 50 knee radiographs were established. Femoral width (FW) and the distance from the AT to the JL (ATJL) were measured on anteroposterior radiographs, and the femoral diameter (FD) was measured on true lateral views. The individual ratio of FW and FD to ATJL was calculated using linear regression analysis. Intraobserver and interobserver reliability was assessed. In order to test the accuracy of the ratio calculated, we also recorded the FW and ATJL of 20 additional knees by magnetic resonance images.
    Results: There are significant differences between genders with these parameters. A linear correlation was found between FW and ATJL (r(2) = 0.7201), which was more reliable than the correlation between FD and ATJL (r(2) = 0.3918). Interobserver repeatability was better for ATJL and FW than for FD. The mean ratio of ATJL/FW was 0.560 +/- 0.03, and there was no statistical difference between men and women. After using this ratio formulas in those data measured from knee magnetic resonance imaging, all cases revealed reliability with 100% cases lying in a 4-mm error margin.
    Conclusion: The AT can be used as a reliable landmark to determine the knee JL position, and the formulas for calculating the ATJL with FW can be applied, making intraoperative identification and judgment easier. (C) 2016 Elsevier Inc. All rights reserved.

  • 推荐引用方式
    GB/T 7714:
    Xiao Jianlin,Wang Shengqun,Chen Wei, et al. A Study to Assess the Accuracy of Adductor Tubercle as a Reliable Landmark Used to Determine the Joint Line of the Knee in a Chinese Population [J].JOURNAL OF ARTHROPLASTY,2017,32(4):1351-1355.
  • APA:
    Xiao Jianlin,Wang Shengqun,Chen Wei,Yang Yuhui,&Zuo Jianlin.(2017).A Study to Assess the Accuracy of Adductor Tubercle as a Reliable Landmark Used to Determine the Joint Line of the Knee in a Chinese Population .JOURNAL OF ARTHROPLASTY,32(4):1351-1355.
  • MLA:
    Xiao Jianlin, et al. "A Study to Assess the Accuracy of Adductor Tubercle as a Reliable Landmark Used to Determine the Joint Line of the Knee in a Chinese Population" .JOURNAL OF ARTHROPLASTY 32,4(2017):1351-1355.
  • 条目包含文件:
    文件类型:PDF,文件大小:
    正在加载全文
浏览次数:35 下载次数:0
浏览次数:35
下载次数:0
打印次数:0
浏览器支持: Google Chrome   火狐   360浏览器极速模式(8.0+极速模式) 
返回顶部